Model |
Mars-5G1-LE |
Mars-6G1-LE |
Mars-8G1-LE |
Mars-10G1-LE |
Mars-12G1-LE |
Mars-14G1-LE |
Battery Input |
Battery Type |
Lead-acid or Lithium-ion |
Battery Voltage Range (V) |
40~60 |
Max. Charge Current (A) |
120 |
130 |
200 |
220 |
250 |
280 |
Max. Discharge Current (A) |
120 |
130 |
200 |
220 |
250 |
280 |
Charging Curve |
3 Stages / Equalization |
External Temperature Sensor |
Yes |
Charging Strategy for Li-Ion Battery |
Self-adaption to BMS |
PV String Input |
Max. DC Input Power (W) |
7500 |
9000 |
12000 |
15000 |
18000 |
20000 |
PV Input Voltage (V) |
650 (160~800) |
MPPT Range (V) |
200~700 |
Full Load DC Voltage Range (V) |
260~650 |
Start-up Voltage (V) |
160 |
PV Input Current (A) |
17+17 |
26+17 |
Max. PV Isc (A) |
20+20 |
34+20 |
No. of MPPT Trackers |
2 |
No. of String per MPPT Trackers |
1+1 |
2+1 |
AC Output |
Rated AC Output and UPS Power (W) |
5000 |
6000 |
8000 |
10000 |
12000 |
14000 |
Max. AC Output Power (W) |
6000 |
7200 |
9600 |
12000 |
13200 |
15400 |
Peak Power (off grid) |
2 times of rated power, 10s |
1.8 times of rated power, 10s |
AC Output Rated Current (A) |
7.6/7.3 |
9.1/8.7 |
12.1/11.6 |
15.2/14.5 |
18.2/17.4 |
21.2/20.3 |
Max. AC Current (A) |
11.4/10.9 |
13.6/13 |
18.2/17.4 |
22.7/21.7 |
27.3/26.1 |
27.6/26.4 |
Max. Continuous AC Passthrough (A) |
30 |
50 |
Power Factor |
0.8 leading to 0.8 lagging |
Output Frequency and Voltage (V) |
50/60Hz, 380/400Vac(Triple phase) |
Grid Type |
Triple phase |
Current Harmonic Distortion |
THD<3% (Linear load<1.5%) |
Efficiency |
Max. Efficiency |
96.60% |
Euro Efficiency |
96.60% |
MPPT Efficiency |
99.90% |
Protection |
Integrated |
PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation
Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection |
PV Arc Fault Detection |
Optional |
Output Over Voltage Protection |
DC Type II / AC Type III |
Certifications and Standards |
Grid Regulation |
CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699,C10-11 |
Safety Regulation |
IEC/EN62109-1, IEC/EN62109-2 |
EMC |
IEC/EN 61000-6-1,IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4 |
General Data |
Operating Temperature Range (°C) |
-40~60, >45 Derating |
Cooling |
Smart Cooling |
Noise (dB) |
≤45 |
Communication with BMS |
RS485; CAN |
Weight (kg) |
38 |
40 |
42 |
44 |
44 |
45 |
Dimensions (mm) |
510Wx630Hx290D |
Protection Degree |
IP65 |
Installation Style |
Wall-mounted |
Warranty |
5 years |